Siemens SIMATIC MV440 Operating Instructions Manual page 126

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

Connecting
7.3 Connecting components
Pin assignment of the Power IO RS232 cable
NOTICE
INPUT - COMMON / OUTPUT - COMMON must be connected
INPUT - COMMON / OUTPUT - COMMON must be connected before you can use the
inputs and outputs detailed below.
Table 7- 1
SIMATIC MV440
Pin
Color
Signal name
H
Red
24 V DC
G
Blue
0 V
K
Violet
INPUT1
D
Yellow
INPUT /
OUTPUT2
L
Gray/
INPUT /
pink
OUTPUT3
C
Green
INPUT /
OUTPUT4
B
Brown
INPUT /
OUTPUT5
A
White
INPUT -
COMMON
E
Gray
OUTPUT -
COMMON
J
Black
STROBE
(OUTPUT)
F
Pink
RS232 TXD
M
Red/blue
RS232 RXD
124
Possible values
TRG
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
DISA, SEL0, SEL1, SEL2, SEL3, TRN,
RES, IN_OP, TRD, RDY, READ,
MATCH, N_OK, EXT_1, EXT_2,
EXT_3, EXT_4
P type inputs/outputs:
INPUT - COMMON = 0 V and
OUTPUT - COMMON = + 24 V DC
N type inputs/outputs:
INPUT - COMMON = + 24 V DC and
OUTPUT - COMMON = 0 V
Default
Meaning
Power supply
Power supply
TRG
Trigger input
IN_OP
Freely selectable input
or output.
RDY
Freely selectable input
or output.
READ
Freely selectable input
or output.
N_OK
Freely selectable input
or output.
Reference point 0 V or
24 V for inputs.
Reference point 0 V or
24 V for outputs.
Signal output for
connecting external
flashes
RS232 send line
RS232 receive line