"Image buffer size > 1" setting
With image buffer sizes greater than 1, intermediate buffering takes place between image
acquisition and processing and between processing and result output. In other words: Image
acquisition can at times be performed in a faster sequence and processing can also buffer
results briefly prior to transfer. This allows brief periods of peak load to be handled.
Object
Trigger
Image acquisition
Decoding
Results transfer
Figure 4-16
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Image buffer size
Cycle time limit
Cycle time
Time diagram of option single trigger for image buffer size > 1; buffer = 2 in this example
4.4 Options for image acquisition and image processing
Image processing
87