4.2.8.4

Standard report for AS9132, Rev A

Field name (TAG)
Verification type (Qt)
Evaluation (Qs)
Overall grade (Q0)
Module size offset grade (Q20)
Module size offset 1 (q20)
Module size offset 2 (q20)
Module center offset grade (Q19)
Module center offset 1 (q19)
Module center offset 2 (q19)
Angle of distortion grade (Q22)
Angle of distortion (q22)
Ovality grade (Q23)
Ovality (q23)
Module fill X (q9)
Module fill Y (q9)
Contrast (q1)
Nominal module size (q10)
ECCLevel (q14)
Height (q15)
Width (q16)
Angle (q17)
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Value
3
If the exposure settings do not comply with the
standard: D
3 (Good), 2 (Fair) or 1 (Poor)
4, 3, 2, 1 or 0
4, 3 or 0
0 ... 99.9
0 ... 99.9
4, 3 or 0
0 ... 99.9
0 ... 99.9
4, 3 or 0
-45 ... 45
4, 3 or 0
0.00 ... 99.9
0 ... 200
0 ... 200
0 ... 100
0 ... 99.9 mil
200
0 ... 9.99 inches
0 ... 9.99 inches
0 ... 360°