Note
If the selected program is not saved, TRD and RDY will retain the value 0.
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Input
Output
Description
DISA=1
Program selection is prepared.
TRN=0
DISA must have the value 1. No edge change is necessary.
TRG=0
RES=0
SEL0=1
Select program, for example, program 11.
SEL1=1
SEL2=0
SEL3=1
TRD=0
Program selection is started.
RDY=0
TRD=1
Program change is completed after approximately 150 ms to 15 s.
RDY=1
Process interfacing via an automation system (PLC, PC)
10.5 Controlling the I/O interface "DI/DO"