Alarm, fault and system messages
11.2 Reporting diagnostics information
11.2.4

Read and verification error messages

If there is a read error or verification error, the following error codes or English message
strings are output. For further information, please refer to "Overall results" in the online help.
Note
The causes of error 4700 to 4722 are also output in the verification report if there is a
verification error
All verification grades are output in the report as "E". The verification values correspond to
the error code.
Note
Evaluating verification errors as read errors
If the "Evaluate quality 'Poor' as 'N_OK'" check box has been selected in the decoding
settings, a verification error will also be evaluated as 'N_OK'.
Error code
Message (%s)
(%c)
0001
No 1D/2D code found in step n
0002
Cycletime too short
0003
Trigger too fast
0004
Non ECC200 Code in step n
0005
Step n: Structured Append DMC not supported
0006
Step n: Reader Programming DMC not supported A DMC type "Reader Programming Code" was found
0007
Step n: QR ECI encoding not supported
0008
Step n: QR Byte encoding not supported
0009
Step n: QR Kanji encoding not supported
0010
Step n: Structured Append QR code not
supported
0011
Step n: QR FNC1 encoding not supported
0012
Quality is poor in step n
0013
Nothing found
342
Description
No code found in step #n.
The processing was not completed within the cycle
time limit.
The processing was interrupted by a trigger signal.
Data matrix code found in step #n that does not
comply with ECC200.
Note
The check for ECC200 is performed only in
adjustment mode and during "Save program".
A DMC type "Structured Append" was found in step n.
This DMC type is not supported.
in step #n. This DMC type is not supported.
A QR code with "ECI encoding" was found in step #n.
This QR type is not supported.
A QR code with "Byte encoding" was found in step #n.
This QR type is not supported.
A QR code with "Kanji encoding" was found in
step #n. This QR type is not supported.
A QR type "Structured Append" was found in step #n.
This QR type is not supported.
A QR code with "FNC1 encoding" was found in
step #n. This QR type is not supported.
A code with the quality evaluation "Poor" was read in
verification mode in step #n.
"Scan" or "Autotrigger edge triggered" mode: All
image acquisitions were decoded without result.
SIMATIC MV420 / SIMATIC MV440