Siemens SIMATIC MV440 Operating Instructions Manual page 177

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

LEDs
In the "LEDs" dialog box, you specify the output signal with which the freely programmable
LED displays are to be connected.
● SIMATIC MV440: Two freely programmable LEDs
● SIMATIC MV420: One freely programmable LED display
DI/DO
You set the switching time of the digital outputs READ, MATCH, N_OK and
EXT_1 to EXT_4.
Beep tone (acoustic signal)
You configure the acoustic sensor. The beep tone only exists with the SIMATIC MV420.
Table 9- 5
Task
Adjustment
Processing mode Off, READ,
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Configuring the acoustic sensor
Possible
Default
values
Off, READ
READ
Off
MATCH, N_OK
Operator control and monitoring
9.2 Working with the user interface
Meaning
Configures the acoustic signal (beep tone) for
adjustment mode.
OFF: No signal
READ: Short acoustic signal when code
could be read. (The higher the tone, the
better the read reliability of the code.)
Configures the acoustic signal (beep tone) for
evaluation mode (RUN).
OFF: No signal
READ: Short acoustic signal when code
could be read. (The higher the tone, the
better the read reliability of the code.)
MATCH: Acoustic signal when the code
comparison was successful.
N_OK: Acoustic signal when reading was
not possible.