Alarm, fault and system messages
11.2 Reporting diagnostics information
Error code
Message (%s)
(%c)
4717
ISO Verification failed RDA STEP A E in step n
4718
ISO Verification failed RDA final image
adjustment in step n
4719
ISO Verification failed RDA error correction in
step n
4720
ISO Verification DM Row/Column too large in step
n
4721
ISO Verification cell size smaller than Min X in
step n
4722
ISO Verification cell size larger than Max X in step
n
11.2.5

Filter error messages

If there is a filter error, the following message strings are displayed in English. For further
information, please refer to "Overall results" in the online help.
Error text (%s)
Symbol does not use GS1-
encoding
"[Number]" is no valid GS1
Application Identifier
GS1 Application Identifier
"[Number]" not found in symbol
content
Symbol content shorter than
given "start position"
ID or separator not found in
symbol content
344
Description
"ISO 15415" or "AIM DPM" verification reports an
error during the reference decoding according to
ISO/IEC 16022:2006 in step a) to e). The error
occurred in step #n.
"AIM DPM" verification reports an error in the final
adjustment of the image. The error occurred in
step #n.
"ISO15415" or "AIM DPM" verification reports: Error
correction in reference decoding algorithm according
to ISO/IEC 16022:2006 failed. The error occurred in
step #n.
"ISO15415" or "AIM DPM" verification reports: A data
matrix larger than 104 x 104 is not supported. The
error occurred in step #n.
"AIM DPM" verification reports: Cell size is smaller
than the configured "Min. X" dimension. The error
occurred in step #n.
"AIM DPM" verification reports: Cell size is larger that
the configured "Max. X" dimension. The error
occurred in step #n.
For filter mode only
Description
GS1
The code read does not begin with the GS1
start symbol "]d2".
GS1
The string selected in the "Filter ID" box
contains an invalid application identifier tag.
GS1
An application identifier specified in the
"Filter ID" box was not found in the read
code.
Position
The read code is shorter than the selected
"Start position"
ID
An ID (field: "Filter ID") or a separator
character (field: "Separators") was not
found in the read code.
Operating Instructions, 04/2013, A5E02371045-06