Siemens SIMATIC MV440 Operating Instructions Manual page 286

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

Process interfacing via an automation system (PLC, PC)
10.4 Control with FB79
Permitted values for the COMMAND parameter
Value (W#16#...)
Meaning
0000
Cancel current job or no job
0001
Change program
0002
Save program
0003
Output number of the program currently selected on the reader
0004
Output the current status of the reader
0005
Reset DISA control signal
0081
Output the (possibly modified) result string
0082
Output absolute quality parameters
0083
Output absolute quality parameters and output result string
0084
Output quality parameters as classes
0085
Output quality parameters as classes and output result string
0086
Output quality parameters as classes and in absolute format
0087
Output quality parameters as classes and in absolute format and output result string
0088
Output code position
0089
Output code position and result string
008A
Output code position and absolute quality parameters
008B
Output code position and absolute quality parameters and output result string
008C
Output code position and quality parameters as classes
008D
Output code position and quality parameters as classes and output result string
008E
Output code position and quality parameters as classes and in absolute format
008F
Output code position and quality parameters as classes and in absolute format and output result
string
Note
To process this job, the following parameters must be set in PROFINET IO:
• Connections ➜ Integration ➜ Text: PROFINET IO
Output of the result string (except commands 4 and 5)
• Connections ➜ Integration ➜ Controller: PROFINET IO
Interface for the DISA, SEL0 to SEL3, TRN, RES, IN_OP, TRD, RDY signals
284
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06

Hide quick links: