Connecting
7.3 Connecting components
The following cable assignment is defined for the connection to the ASM 475:
Figure 7-2
Pin M16 socket
Wire color of the connecting cable
H
Red
G
Blue
F
Pink
M
Red/blue
B
Brown
C
Green
Ethernet cable M12/RJ-45
● With a preassembled Ethernet cable, you connect a PC / PG to control and operate the
reader.
● Attach the Ethernet cable to a switch to connect the reader to an automation system via
onboard PROFINET IO.
126
Status and error displays
Wiring diagram; the numbers of the connection refer to the X1 connector of the upper housing
Front panel and inside of the front door of the ASM475 module
Terminal ASM475 (Channel 1/Channel 2)
8 / 16
9 / 17
4 / 12
5 / 13
6 / 14
7 / 15
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06