Alarm, fault and system messages
11.2 Reporting diagnostics information
Message
Value
(onboard
PROFINET
diagnostics)
Error - transfer
W#16#5007
error ASM/
PROFINET IO
Error saving
W#16#500A
code
Error - match
W#16#500B
error
Error
W#16#500C
No ECC 200
code
Error
W#16#500E
TCP
communication
336
Value
Value
(TCP/IP and
(FB45,
RS232)
error_MOBY)
07
0A
10
02
11
0E
12
02
14
0C
Value
Description
(Ident
profile,
STATUS
byte)
(byte 0,
byte 1,
byte 2)
E1, FE, 04 The send buffer is
full because the
data cannot be
queried in an
adequately short
time.
E6, FE, 04 No code was found
in the image during
program saving.
E1, FE, 07 The saved code
cannot be
processed with the
match settings (for
example
ID/separator not
found)
E6, FE, 04 The code found
during saving does
not comply with the
ECC 200 standard.
Note:
Applies only to the
ID-Genius decoder.
E1, FE, 01 Connection error in
communication
over a TCP
connection or when
using an Ethernet
RS232 converter:
There is no TCP
connection or the
data transfer
cannot be
completed within
the set time limit.
Operating Instructions, 04/2013, A5E02371045-06
How to remedy the
problem
Reduce the trigger
frequency or process the
results more quickly on
the CPU. If necessary,
the baud rate on the
ASM connection can
also be increased
To cover short peaks,
the image buffer size of
the program under
Image acquisition,
"Control" tab can be
increased.
Position the code within
the image or improve the
image quality.
Adapt the match
settings, or save a
suitable code.
Use a code conforming
to the standard or
change to the standard
decoder.
Make sure that the
connected TCP partner
is correctly configured
and ready to receive.