Initialization - Siemens SIMATIC MV440 Operating Instructions Manual

Simatic ident code reader system
Hide thumbs Also See for SIMATIC MV440:
Table of Contents

Advertisement

10.3.3.2

Initialization

To perform the the initialization (FB45: init_run, Ident profile: INIT), you have the choice
between an initialization without program selection and initialization with program selection.
To react to a change in the operating mode and to check the preconditions to be fulfilled
(Preconditions for the commands (Page 265)):
● Monitor the operating mode state of the reader regardless of the initialization method
selected by the automation system (Status displays of the MV reader (Page 245)).
Initialization without program selection
Initialization without program selection enables:
● Initialization after startup
– After the self-test, the reader changes to the operating mode that it was in prior to
– Initialization is possible during the self-test. You need to determine the operating mode
● Identification of pending error (Group errors (Page 267))
● Reset of pending error
Initialization with program selection
Initialization with program selection enables:
● Initialization after startup
– After the self-test, the reader switches to processing mode with the selected program
– Initialization during self-test is not possible (negative acknowledgment is received).
● Reset of pending error with the subsequent start of the selected program. If the selected
program does not exist, the initialization is acknowledged negatively.
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
shutdown.
using the status display (Status displays of the MV reader (Page 245)).
number.
Process interfacing via an automation system (PLC, PC)
10.3 Control with FB 45 and Ident profile
247