11.2.3

Read results

Cons.
Message
no.
1
Read error (<reason>)
2
Filter error (<reason>)
3
Match error(<read result> !
<Match string>)
4
Format error(<reason>)
Note
Changing error texts
Please note that the error texts on the "Results" tab (results step) under "Programs" can
change.
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
Description
The processing was not successful in
processing mode.
The selected result string filtering
was not possible with the read code.
The configured comparison option
was not found in the code to be
compared.
The string defined for training
does not match the current string
of the code or the plain text.
The configured format text does not
match the definition.
Alarm, fault and system messages
11.2 Reporting diagnostics information
How to remedy the problem
For possible causes, refer to "Read and
verification error messages" for the error
messages.
1. Check whether the code just read is
correct.
2. Check and, if necessary, correct the
selected result settings in the decoder
step in the "Result" tab.
1. The code or plain text that has just
been read deviates from the trained
code (and is therefore incorrect), or the
wrong code was trained.
2. Check the selected result settings.
Check the selected settings.
You can find additional information in
"Overall result" in the online help.
The undefined formatting command is
issued as <reason>.