Standard Report for AIM DPM-1-2006

Field name (TAG)
Verification type (Qt)
Evaluation (Qs)
Overall grade (Q0)
Reference decode grade (Q7)
Cell contrast grade (Q1)
Cell contrast (q1)
Axial non-uniformity grade (Q2)
Axial non-uniformity (q2)
Grid non-uniformity grade (Q3)
Grid non-uniformity (q3)
Unused error correction grade (Q4)
Unused error correction (q4)
Fixed pattern damage grade (Q5)
Cell modulation grade (Q6)
Minimum reflectance grade (Q8)
Minimum reflectance (q8)
Print growth X (q9)
Print growth Y (q9)
Cell size (q10)
Current mean light (q11)
Aperture (q12)
Percentage aperture (q13)
ECCLevel (q14)
Height (q15)
Width (q16)
Angle (q17)
4.2.8.6

Standard report for the "ID-Genius" decoder

Field name (TAG)
Overall grade (Q0)
Symbol contrast grade (Q1)
Symbol contrast (q1)
Axial non-uniformity grade (Q2)
Axial non-uniformity (q2)
Unused error correction grade (Q4)
Unused error correction (q4)
Print growth grade (Q9)
Print growth (q9)
72
Value
1
If the exposure settings do not comply with the
standard: B
3 (Good), 2 (Fair) or 1 (Poor)
4, 3, 2, 1 or 0
4, 3, 2, 1 or 0
4, 3, 2, 1 or 0
0 ... 100
4, 3, 2, 1 or 0
0.00 ... 1.00
4, 3, 2, 1, or 0
0.00 ... 1.00
4, 3, 2, 1 or 0
0.00 ... 1.00
4, 3, 2, 1 or 0
4, 3, 2, 1 or 0
4, 3, 2, 1 or 0
0 ... 100
-100 ... 100
-100 ... 100
0 ... 99.9 mil
0 ... 255
0 ... 999
50, 80 or 0
200
0 ... 9.99 inches
0 ... 9.99 inches
0 ... 360°
Value
4, 3, 2, 1 or 0
4, 3, 2, 1 or 0
0 ... 100
4, 3, 2, 1 or 0
0.00 ... 1.00
4, 3, 2, 1 or 0
0.00 ... 1.00
4, 3, 2, 1 or 0
-999 ... 999