5.4 System Control—System Shutdown
In order to turn off the power to a PBX, it must first be issued a shutdown command using Web Maintenance
Console. Follow the procedure below to prepare a PBX for system shutdown.
When the system is shut down, any settings not saved to the System Memory are lost. A backup should be
performed before the shutdown to ensure no data is lost. However, a backup should not be performed if settings
or data have recently been imported into the system, because performing a backup would overwrite the
imported data with the current PBX settings.
This screen can be accessed only in On-line mode.
1.
Confirm the contents of the displayed warning message.
2.
Click Backup or Skip according to the system's status:
Backup: Click to backup system settings. The system will prepare for shutdown after the backup has
been performed.
Skip: The system is prepared for shutdown without performing a backup.
3.
The STATUS LED on the front of the PBX will flash amber. When shutdown preparations are completed,
the STATUS LED will stop flashing and remain a solid amber. Once the STATUS LED stops flashing, you
may turn off the power switch on the back of the PBX.