2.7.6 Verification Code Entry
2.24.1 Extension Personal Identification Number (PIN)
External Sensor—Ring Duration (s)
Specifies the length of time that the PBX waits for the called party to answer before cancelling a sensor call.
Value Range
10 ´ n (n=1–15) s
Maintenance Console Location
10.3 PBX Configuration—[2-3] System—Timers & Counters
Feature Guide References
2.18.3 External Sensor
Incoming Call Inter-digit Timer—DDI / DID (s)
Specifies the length of time between digits when receiving a DDI/DID number from a public network. The call
will be redirected to a PBX operator when this timer expires.
Value Range
0–30 s
Maintenance Console Location
10.3 PBX Configuration—[2-3] System—Timers & Counters
PC Programming Manual References
18.3 PBX Configuration—[10-3] CO & Incoming Call—DDI / DID Table
Feature Guide References
2.1.1.3 Direct Inward Dialling (DID)/Direct Dialling In (DDI)
Incoming Call Inter-digit Timer—TIE (s)
Specifies the length of time between digits when receiving a dialled number from a TIE line. The call will be
redirected to a PBX operator when this timer expires.
Value Range
3–30 s
Maintenance Console Location
10.3 PBX Configuration—[2-3] System—Timers & Counters
10.3 PBX Configuration—[2-3] System—Timers & Counters
PC Programming Manual
449