Property Setting—Select Service Provider
Select the SIP service provider after importing SIP service provider file.
Value Range
Max. 100 characters
Maintenance Console Location
9.4.2 PBX Configuration—[1-1] Configuration—Slot—VoIP Property—VoIP (Trunk) Setting
Property Setting—Register Ability
Specifies whether to send the REGISTER message to the SIP server.
Value Range
Disable, Enable
Maintenance Console Location
9.4.2 PBX Configuration—[1-1] Configuration—Slot—VoIP Property—VoIP (Trunk) Setting
Property Setting—Session Expire Timer (s)
Specifies the length of time that the PBX waits before terminating SIP sessions when no reply to the repeated
requests is received.
Value Range
90–3600 s
Maintenance Console Location
9.4.2 PBX Configuration—[1-1] Configuration—Slot—VoIP Property—VoIP (Trunk) Setting
Property Setting—From Header - user Part
Specifies the value to be stored in the username part of the SIP-URI of the From header.
Value Range
User Name, Authentication ID, PBX-CLIP
Maintenance Console Location
9.4.2 PBX Configuration—[1-1] Configuration—Slot—VoIP Property—VoIP (Trunk) Setting
Property Setting—Header Type
Specifies the header of the SIP message in which the caller information is stored.
Value Range
From Header, P-Preferred-Identity Header
9.4.2 PBX Configuration—[1-1] Configuration—Slot—VoIP Property—VoIP (Trunk) Setting