9.16 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT—Port Property
FAX/T.38
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common Programming
Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Extension Number
Specifies the extension number of the port.
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
9.16 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT—Port Property
Feature Guide References
5.2.2 SIP (Session Initiation Protocol) Extension
Password
Specifies the password used for registering a SIP Extension to the PBX. While it is possible to enter a password
manually for each SIP Extension, you can copy the value for
the Copy to button. This parameter can only be modified when the virtual SIP extension port is set to OUS,
and the programmer must be in On-line mode.
Value Range
4–16 characters (consisting of 0–9, a–z, A–Z)
Maintenance Console Location
9.16 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT—Port Property
Feature Guide References
5.2.2 SIP (Session Initiation Protocol) Extension
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port. This option is only available in On-line mode.
Value Range
INS: The port is in service
OUS: The port is out of service
Fault: The port is not communicating with the network.
Maintenance Console Location
9.16 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT—Port Property