9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Value Range
1–65535
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection
IP Extension—Keep Alive Packet Type
Specifies the type of Keep Alive packets to be sent out for remote connections for IP extensions.
Value Range
Blank UDP, None
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection
IP Extension—Keep Alive Packet Sending Interval Time (s)
Specifies the time interval between transmissions of Keep Alive packets.
Value Range
10–60 s
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection
SIP Extension / UT Extension—NAT - SIP Proxy Server Port No.
Specifies the outside-facing port of the network gateway connected to the SIP proxy server.
Value Range
1–65535
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site