9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Remove Digit
Specifies the number of leading digits of the CLIP number to be removed. This setting is compulsory when
PBX-CLIP is selected in From Header—User Part or P-Preferred-Identity Header—User Part.
Value Range
0–32
Maintenance Console Location
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Additional Dial
Specifies the number to be added to the CLIP number in the place of the removed digits. This setting is
compulsory when PBX-CLIP is selected in From Header—User Part or P-Preferred-Identity Header—User
Part.
Value Range
Max. 20 digits (consisting of 0–9, *, and #)
Maintenance Console Location
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Anonymous format in "From" header
Specifies the format of the "From" header when not sending caller ID.
Value Range
Display name and SIP-URI, Display name only
Note
If "Display name and SIP-URI" is selected, the display name part and the SIP-URI of the "From" header
will be displayed as "Anonymous".
[Example]
From: Anonymous <sip:anonymous@anonymous.invalid>
If "Display name only" is selected, only the display name part of the "From" header will be displayed as
"Anonymous".
[Example]
From: Anonymous <sip:1234@example.com>
Maintenance Console Location
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
P-Asserted-Identity header
Select whether to include a P-Asserted-Identity header with caller information. This header will be sent
independent of the selection for
Value Range
Disable, Enable