20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting
PC Programming Manual References
24.4 UM Configuration—[5-4] System Parameters—Parameters—PBX Parameters—
Environment—Extension Transfer Sequence (Up to 16 digits / [0-9 * # D R F T X , ;])
Feature Guide References
3.2.2.7 Call Transfer Status
Call Transfer Sequence (Other)
Specifies the Call Transfer Sequence used by the mailbox. Only specified if
(Selection) is set to "Other".
Value Range
Enter a maximum of 16 characters consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause (default 1 s)
; : Dial Pause (default 3 s)
X: Extension Dialling
0–9,
, #: Dial Code
Maintenance Console Location
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting—Mailbox Parameters
Feature Guide References
3.2.2.7 Call Transfer Status
No Answer Time (Selection/Other)
Specifies the length of time that the Unified Messaging system waits before handling unanswered calls to the
extension.
Note
When "System" is selected, the Unified Messaging system uses the time pre-programmed in 24.4 UM
Configuration—[5-4] System Parameters—Parameters—Dialling Parameters/MSW Notification—
Dialling Parameters—Call Transfer No Answer Time (10-60 s).
Value Range
System, Other (If "Other" is selected, specify 10–60 s)
Maintenance Console Location
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting—Mailbox Parameters