Maintenance Console Location
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Register
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Register Ability
Specifies whether to send the REGISTER message to the SIP server.
Value Range
Disable, Enable
Maintenance Console Location
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Register Sending Interval
Specifies the maximum length of interval time after which the PBX sends the REGISTER message.
Value Range
10–86400 s
Maintenance Console Location
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Un-Register Ability when port INS
Specifies whether to unregister the previous registration and send the REGISTER message to the SIP server
when the port status is set back to INS.
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property