13 VoIP
404
Field
Called Address
Add and configure routing entries under Routing Rules. You can also delete routing
entries.
Use Add to create entries.
Fields in the Call Routing Routing Rules menu (only if Type is not Deny)
Field
Priority
Administrative Status
Outbound Line
Trunk Line
Called Address Transla-
tion
Funkwerk Enterprise Communications GmbH
Description
You can enter an address numerically (e.g. a subscriber num-
ber) or alphanumerically (e.g. for a trunk) that is to be compared
with a dialled address.
The following wildcards can be used:
• * means that at the end of a character string an arbitrary num-
ber of any characters can follow,
• ? is a placeholder for an arbitrary character.
If the configured address agrees with the signalled address, the
routing entry is used.
Description
Enter a whole number starting with 1 in ascending order to
define the order of filter rules.
The rules are worked through in the order given in the list.
If a line or SIP account is not available, the next rule is automat-
ically used.
Select whether the filter rule should be activated.
The rule is activated with Enabled.
The rule is active by default.
Choose the PSTN line (PRI, BRI, FXO) used for the outgoing
call.
Only for Type = Trunk.
Choose the PSTN SIP account used for the outgoing call.
Enter how the subscriber number is manipulated before it is
used for dialling.
bintec R1xxx/R3xxx/R4xxx