ABB REG650 Technical Manual page 399

Generator protection
Hide thumbs Also See for REG650:
Table of Contents

Advertisement

1MRK 502 034-UEN -
Name
Values (Range)
OverTrigOp01
OverTrigLe01
NomValue02
UnderTrigOp02
UnderTrigLe02
OverTrigOp02
OverTrigLe02
NomValue03
UnderTrigOp03
UnderTrigLe03
OverTrigOp03
OverTrigLe03
NomValue04
UnderTrigOp04
UnderTrigLe04
OverTrigOp04
OverTrigLe04
NomValue05
UnderTrigOp05
UnderTrigLe05
OverTrigOp05
OverTrigLe05
NomValue06
UnderTrigOp06
UnderTrigLe06
OverTrigOp06
Table continues on next page
Technical Manual
Unit
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
0 - 5000
%
0.0 - 999999.9
-
Off
-
On
0 - 200
%
Off
-
On
Step
Default
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
1
200
0.1
0.0
-
Off
1
50
-
Off
Section 13
Monitoring
Description
Use over level trigger for analog channel
1 (on) or not (off)
Over trigger level for analog channel 1 in
% of signal
Nominal value for analog channel 2
Use under level trigger for analog
channel 2 (on) or not (off)
Under trigger level for analog channel 2
in % of signal
Use over level trigger for analog channel
2 (on) or not (off)
Over trigger level for analog channel 2 in
% of signal
Nominal value for analog channel 3
Use under level trigger for analog
channel 3 (on) or not (off)
Under trigger level for analog channel 3
in % of signal
Use over level trigger for analog channel
3 (on) or not (off)
Overtrigger level for analog channel 3 in
% of signal
Nominal value for analog channel 4
Use under level trigger for analog
channel 4 (on) or not (off)
Under trigger level for analog channel 4
in % of signal
Use over level trigger for analog channel
4 (on) or not (off)
Over trigger level for analog channel 4 in
% of signal
Nominal value for analog channel 5
Use under level trigger for analog
channel 5 (on) or not (off)
Under trigger level for analog channel 5
in % of signal
Use over level trigger for analog channel
5 (on) or not (off)
Over trigger level for analog channel 5 in
% of signal
Nominal value for analog channel 6
Use under level trigger for analog
channel 6 (on) or not (off)
Under trigger level for analog channel 6
in % of signal
Use over level trigger for analog channel
6 (on) or not (off)
393