Toro Z Master Z597 Service Manual page 135

Diesel series
Table of Contents

Advertisement

ELECTRICAL
Step 1 Testing the "timed" output in the "run"
position (Fig. 367).
set for K
RED
BLACK
A. Set VOM to read continuity in K ohms.
B. Connect the red lead to referenced
terminal "A" of the glow plug timer.
C. Connect the negative lead to the
negative terminal of the battery.
D. Connect a jumper lead from terminal "D"
of the timer to the negative terminal of
the battery.
E. Connect terminal "C" of the timer to
the positive terminal of the battery and
watch the meter. The meter should read
continuity then increasing resistance
until it reads "open". The timeframe
should be approximately 10 seconds
6
from reading continuity to reading
"open".
6-14
Fig 367
glow plug timer test 2
Step 2 Testing continuous output in the "START"
position (Fig. 368).
set for K
RED
BLACK
Fig 368
A. Set VOM to read K ohms.
B. Connect the red lead to terminal "A" of
the glow plug timer.
C. Connect the black lead to the negative
terminal of the battery.
D. Connect a jumper lead from terminal "D"
of the timer to the negative terminal of
the battery.
E. Connect a jumper lead from terminal "B"
of the timer to the positive terminal of
the battery. The meter should hold at a
constant continuity reading. The timer is
reactivated in a continuous mode as the
machine is being started.
Z Master 597 Diesel Series Service Manual
glow plug timer test 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents