G4 Web Control Settings Page; Passwords - AMX MVP-9000i-GB Instruction Manual

Table of Contents

Advertisement

G4 Web Control Settings Page

An on-board VNC (Virtual Network Computing) server allows the panel to connect to any remote PC running a VNC client. Once
connected, the client can view and control the panel remotely. The options on this page allow you to enable/disable G4 Web
Control functionality (FIG. 87).
G4 Web Control Settings page
FIG. 87
G4 Web Control Settings Page
Back:
WiFi/Wired icon:
Connection Status
icon:
G4 Web Control:
Timeout:
Control Name:
Control Password:
Control Port:
Max Connects:
Connect Count:
NOTE: Refer to the Using G4 Web Control to Interact with a G4 Panel section on page 42 for instructions on using the G4 Web
Control page with the web-based NetLinx Security application.
NOTE: The panel MUST be rebooted to save changes made on this page.

Passwords

The options on the Passwords page (FIG. 88) allow assignment of passwords required for users to access the Protected Setup page,
and to release the device from a Table or Wall Docking Station
Passwords page
FIG. 88
MVP-9000i - Instruction Manual
Saves all changes and returns to the previous page.
The icon to the left of the Connection Status Icon displays whether the current connection to the Master is Wireless
(image of a radio antenna) or Wired (image of three networked computers).
The icon in the upper-right corner of each Protected Setup page provides a constant visual indication of current
connection status.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx Master.
The G4 Web Control button toggles between the two G4 activation settings:
• Off - deactivates G4 Web Control on the panel.
• On - activates G4 Web Control on the panel.
Sets the length of time (in minutes) that the panel can remain idle, detecting no cursor movements, before the G4
Web Control session is terminated.
• Minimum value = Off (panel never times out)
• Maximum value = 4 h (panel times out after 4 hours)
Use this field to enter a unique alpha-numeric string to be used as the panel's display name within the Manage
WebControl Connections window of the NetLinx Security browser window.
Use this field to enter the G4 Authentication session password required for VNC access to the panel. This password is
limited to between 1 and 8 characters.
Use this field to enter the number of the port used by the VNC Web Server. Default = 5900.
Displays the maximum number of users that can be simultaneously connected to this panel via VNC. Default = 1.
Displays the number of users currently connected to this panel via VNC. Default = 1.
.