Calibrate Page

The Calibrate page (FIG. 51) allows you to calibrate the touch panel for maximum sensitivity.


FIG. 51
Calibrate page
If the calibration was improperly set and the Calibrate page cannot be reached
through the panel's firmware, this firmware page may be accessed via G4 Web
Control. Navigate to the Protected Setup page and press the Calibrate button through
the VNC window.
This action causes the panel to go to the Calibrate page seen above, where the touch
panel may be physically re-calibrated again using the above procedures.

G4 Web Control Settings Page

The G4 Web Control Settings page (FIG. 52) centers around enabling and disabling both the display and control of your
panel (via the web). An external PC running a VNC client, installed during the initial communication to the G4 panel,
makes this possible.
FIG. 52
G4 Web Control page
Each panel supports the open standard Virtual Network Computing (VNC) interface.
These panels contain a VNC server that allows them to accept a connection from any other device running a VNC client.
Once a connection is established to that target device, the client can control the touch panel remotely.
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
Press and hold the Front Setup Access button for 6 seconds to access the Calibrate page.
Press the crosshairs to calibrate the panel and return to the last active firmware page.