Pre-Wall Installation of the CB-MVP-WDS9

1.
Remove the rough-in box cover (A in FIG. 16) before installation of the Rough-In Box (B).
NOTE: The cover MUST be removed before drywall installation. The cover may be reinstalled after drywall installation using 4-40
screws (not included).
2.
Fasten the CB-MVP-WDS9 rough-in box to the stud through the holes on the Stud Mounting Tabs, using either nails or screws
(not provided).
NOTE: Ensure that the metal rough-in box is flush with the 2x4 studs. Any overhang will affect the installation of the covering
sheetrock, as well as affect the placement of the Plastic Back Box.
3.
Remove the appropriate wiring knockouts from the rough-in box to accommodate the cables being threaded through to the
MVP-WDS-9.
NOTE: Make sure that the power cable has been pulled through the metal rough-in box by the resident electrician before
continuing the installation.
4.
Thread the incoming Ethernet and USB wiring through the knockouts. Using the left wiring knockouts for USB connector
cables and the right wiring knockouts for the LAN/PoE In cable is very highly recommended with this installation. Leave
enough slack in the wiring to accommodate installation of the docking station.
5.
Install the drywall/sheetrock before inserting the back box for the CB-MVP-WDS9.
6.
Cut out the opening for the MVP-WDS-9 where the wall has been placed over the Rough-In Box. Cutting out the surface
slightly smaller than what is outlined in the installation drawings, so that you can make any necessary cutout adjustments, is
very highly recommended.

Other MVP-WDS-9 installations

The Wall-Mounted Docking Station is designed to be installed in various different locations, such as into the face of a wooden
podium or the top of a table. Depending upon the ability to wire it to a power source, Wall-Mounted Docking Stations may be
installed on vertical or horizontal surfaces composed of such materials as wood, brick, and glass.
Installing a Wall-Mounted Docking Station into a solid wall thicker than a standard thickness of sheetrock is possible, but requires
special preparation. If installing into a solid wall of concrete or rock, a recess must be chiselled or cut out to match the size of the
device. The box is sized 8.375 inches (21.27cm) long and 5.75 inches (14.60cm) high, so the hole should be at least 1/4" (0.64cm)
smaller in these dimensions. To facilitate the full range of movement of the device's components, the recess must be at least 2.69
inches (6.83cm) deep.
NOTE: Ensure that the power cable has been installed in the wall and is accessible by the installer before chiseling out the recess.
NOTE: Instead of using the lockdown wings to secure the Plastic Back Box, standard concrete screws may be inserted through the
screw holes after removing the lockdown wings. However, drill the concrete screw holes into the wall before setting the screws into the
box, as excessive torque applied to the screws will damage the box. To avoid this, the box may be installed with adhesive. Test an
unobtrusive spot on the back of the box with a sample of the adhesive to check for any adverse reactions before installing the device.

Undocking from the MVP-TDS-9 or MVP-WDS-9

Once placed within either the Table Docking Station or the Wall Docking Station, the MVP-9000i remains secured until the user
unlocks it. A ten-second lag between the touch panel being placed in either Docking Station and the security feature enabling
allows the user to remove the touch panel if it is accidentally put into the device. To release the touch panel from either Docking
Station:
1.
Press the Release button (see FIG. 6 for the Table Docking Station or FIG. 10 for the Wall Docking Station).
2.
A password keypad will pop up on the MVP-9000i screen. Enter a password in the password keypad and press Enter.
NOTE: Unique passwords may be entered for up to four unique users as well as the administrator. For more information on
setting passwords, please refer to the Passwords section on page 73.
3.
If the MVP-9000i was conducting a SIP call or Dynamo session at this time, a confirmation dialog window appears to warn
that any open sessions or calls will end (FIG. 17).
Click Yes to undock the panel and disconnect the call/session, or No to keep the panel in the Docking Station and continue the