5.
In the lower Bindings for Local Area Connection field, unselect ALL bindings by clicking on the checkboxes by each binding to
remove the checks from each box (FIG. 112).
Bindings for Local area list detail
FIG. 112
6.
When finished, click OK to close the Advanced Settings window and save all changes.

Reverting the MVP-9000i to Factory Default Firmware

In certain circumstances, it may be necessary to return the MVP-9000i to its original factory firmware and settings. To do so, the
procedure may be started either from the touch screen during rebooting, or by accessing the Protected Setup pages.
To revert the MVP-9000i to factory default settings via a reboot:
1.
Reboot the device, either from the Setup page (page 45) or via the Reset button on the left side of the device (FIG. 1). Touch
and hold the touch panel while the device is rebooting, until the "Request for Factory Reset" confirmation screen (FIG. 113)
appears. The Status LED on the right front of the device (FIG. 1 on page 15) will also change color from blue to red.
"Request for factory reset detected" confirmation screen
FIG. 113
2.
Release the touch screen to start the factory reset. The factory reset confirmation screen appears, warning that continuing
with the reset will result in a loss of data (FIG. 114), and the red Status LED will blink on and off. Press Yes within 10 seconds
to continue with the factory reset, or No to continue the reboot with the current settings and firmware.
NOTE: If neither button is pressed within 10 seconds, the Status LED will change back from red to blue and the reboot will
continue.
NOTE: Returning the MVP-9000i to its factory defaults will remove all previous conf iguration settings and user pages.
Factory reset confirmation screen
FIG. 114
3.
The MVP-9000i will now reload its factory default settings and firmware and then reboot.
To revert the MVP-9000i to factory default settings via the Protected Setup pages:
1.
From the Protected Setup page, press the Options button to open the System & Panel Options page (page 56).
2.
In the System Options section, press the Install Firmware button.
3.
In the Firmware Installation popup window, press the Factory button.
MVP-9000i - Instruction Manual