NOTE: The panel-specif ic f irmware is shown on the right of the listed panel. Download the latest f irmware f ile from
www.amx.com and then save the Kit f ile to your computer. Note that each Kit f ile is intended for download to its corresponding
panel. In some cases, several Kit f iles may be included in a .zip f ile; extract the .zip f ile to access the required Kit f ile.
5.
If the panel firmware version is not the latest available; locate the latest firmware file from the www.amx.com > Tech Center
> Firmware Files > Modero Panels section of the website.
6.
Click on the desired Kit file link and after accepting the Licensing Agreement, verify download of the Modero Kit file to a known
location.
7.
Select Tools > Firmware Transfers > Send to NetLinx Device from the main menu to open the Send to NetLinx Device dialog
(FIG. 107). Verify that the panel's System and Device number values match those values listed within the System folder in the
OnLine Tree tab of the Workspace window.
Send to NetLinx Device dialog window
FIG. 107
8.
Select the appropriate Kit file from within the Browse for Folder window (FIG. 108).
Browse for Folder window
FIG. 108
9.
Select the panel's Kit file from the Files section.
10. Enter the Device value associated with the panel and the System number associated with the Master (listed in the OnLine Tree
tab of the Workspace window). The Port f ield is greyed-out.
11. Click the Reboot Device checkbox if it is not already checked. This causes the touch panel to reboot after the firmware update
process is complete.
12. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog.
13. After the file transfer is complete, the panel will automatically reboot. As the panel is rebooting, temporarily unplug the USB
connector on the panel until the panel has completely restarted.
14. Once the first panel page has been displayed, reconnect the USB connector to the panel.
15. Right-click the associated System number and select Refresh System. This causes a refresh of all project systems, establishes
a new connection to the Master, and populates the System list with devices on your particular system.
16. Confirm that the panel has been properly updated to the correct firmware version.