Bfb; Bim; Bln - AMX MVP-9000i-GB Instruction Manual

Table of Contents

Advertisement

"^" Button Commands (Cont.)

^BFB

^BIM

^BLN

MVP-9000i - Instruction Manual
Set the feedback type of the button. ONLY works on General-type buttons.
Syntax:
"'^BFB-<vt addr range>,<feedback type>'"
Variable:
variable text address range = 1 - 4000.
feedback type = (None, Channel, Invert, On (Always on), Momentary, and Blink).
Example:
SEND_COMMAND Panel,"'^BFB-500,Momentary'"
Sets the Feedback type of the button to 'Momentary'.
Set the input mask for the specified address.
Syntax:
"'^BIM-<vt addr range>,<input mask>'"
Variable:
variable text address range = 1 - 4000.
input mask = Refer to the Text Area Input Masking table on page 139 for character types.
Example:
SEND_COMMAND Panel,"'^BIM-500,AAAAAAAAAA'"
Sets the input mask to ten 'A' characters, that are required, to either a letter or digit (entry is required).
Set the number of lines removed equally from the top and bottom of a composite video signal. The maximum number of
lines to remove is 240. A value of 0 will display the incoming video signal unaffected. This command is used to scale non
4x3 video images into non 4x3 video buttons.
Syntax:
"'^BLN-<vt addr range>,<button states range>,<number of lines>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and
2 = On state).
number of lines = 0 - 240.
Example:
SEND_COMMAND Panel,"'^BLN-500,55'"
Equally removes 55 lines from the top and 55 lines from the bottom of the video button.
Programming
102

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvp-9000i-gw