"^" Button Commands (Cont.)

?JSI

^JST

?JST
MVP-9000i - Instruction Manual
Get the current icon justification.
Syntax:
"'?JSI-<vt addr range>,<button states range>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and
2 = On state).
custom event type 1006:
Flag - Zero
Value1 - Button state number
Value2 - 1 - 9 justify
Value3 - Zero
Text - Blank
Text length - Zero
Example:
SEND COMMAND Panel,"'?JSI-529,1'"
Gets the button 'OFF state' icon justification information. The result sent to the Master would be:
ButtonGet Id = 529 Type = 1006
Flag
= 0
VALUE1 = 1
VALUE2 = 6
VALUE3 = 0
TEXT
=
TEXT LENGTH = 0
Set text alignment using a numeric keypad layout for those buttons with a defined address range. The alignment of 0 is
followed by ',<left>,<top>'. The left and top coordinates are relative to the upper left corner of the button.
Syntax:
"'^JST-<vt addr range>,<button states range>,<new text alignment>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and
2 = On state).
new text alignment = Value of 1 - 9 corresponds to the following locations:
0
1
2
3
Zero can be used for an absolute position
4
5
6
7
8
9
Example:
SEND_COMMAND Panel,"'^JST-500.504&510.515,1&2,1'"
Sets the text alignment to the upper left corner for those buttons with variable text ranges of 500-504 & 510-515.
Get the current text justification.
Syntax:
"'?JST-<vt addr range>,<button states range>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and
2 = On state).
custom event type 1004:
Flag - Zero
Value1 - Button state number
Value2 - 1 - 9 justify
Value3 - Zero
Text - Blank
Text length - Zero
Example:
SEND COMMAND Panel,"'?JST-529,1'"
Gets the button 'OFF state' text justification information. The result sent to the Master would be:
ButtonGet Id = 529 Type = 1004
Flag
= 0
VALUE1 = 1
VALUE2 = 1
VALUE3 = 0
TEXT
=
TEXT LENGTH = 0