Installation

Pre-Wall Installation of the Conduit Box

Wall Mount panels (NXDs) are contained within an outer housing (back box). This back box is not removed
when installing the NXD into a Conduit Box (CB-TP10). The back box is only removed to gain access for the
replacement of the internal components.
INSTALLER: LEAVE A GAP BETWEEN THE STUD AND CONDUIT BOX
MOUNTING TABS TO ACCOMMODATE THE DRYWALL or SHEETROCK.
This gap allows the installation of the drywall or sheetrock after the CB-TP10 Conduit
Box has been installed.
The CB-TP10 is an optional metallic box that is secured onto a stud/beam in a pre-wall setting (where no
walls are present). Installation procedures and configurations can vary depending on the installation
environment. This section describes the installation procedures for the most common installation scenario. The
most important thing to remember when mounting this conduit box is that the NXD-1000Vi Mounting Tabs
must lie flush against the outside of the sheetrock (FIG. 19).



1.
Rest the right Stud Mounting tabs onto the stud (keeping the knockouts on the left). Be sure to leave
enough of a gap between the stud and NXD Mounting tabs to accommodate the installation of the
drywall or sheetrock after the conduit box has been mounted. Ultimately, the Mounting Tabs
should lie flush against the outside of the sheetrock.
2.
Fasten the CB-TP10 conduit box to the stud through the holes on the right Stud Mounting tabs (FIG. 19),
using either nails or screws.
Wiring
knockouts
(must be
located on
left side)
FIG. 19
CB-TP10 conduit box components
3.
Remove the wiring knockouts from the left side of the conduit box (CB-TP10) (FIG. 19) to accommodate
the cables being threaded through to the NXD touch panel.
Remember that when mounting this conduit box, the NXD mounting tabs must lie
flush against the outside of the sheetrock.
4.
Thread the incoming power, RJ-45 audio/video, Ethernet, and USB wiring through the knockouts (use of
the left wiring knockouts are recommended with this installation).
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
26
Refer to SP-2259-02 for detailed installation dimensions.
It is recommended that you cut out the surface slightly smaller than what is outlined in the
installation drawings so that you can make any necessary cutout adjustments.
The wiring knockouts on the left side will be used for the NXD-1000Vi Wall Mount panel
connectors, so always secure the conduit box to the stud using the Stud Mounting Holes on the
right side of the box.
Stud Mounting tabs
Drywall or sheetrock
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
Stud
NXD Mounting tabs
(should lie flush against
the outside of the wall)