Number Of Input Details; Behaviour; Extended Settings - Busch-Jaeger Busch-ComfortTouch Product Manual

Table of Contents

Advertisement

20.3.48 Number of input details

20.3.48.1 Behaviour

If this module receives a value (regardless of which data type) via one of the up to eight inputs
(Input 0 to 7), it outputs the index number of the received input on the Output 0. If the module
receives values on multiple inputs simultaneously, the highest index number is output.
The internal data type of the module is Number. If necessary, incoming values are converted
before the calculation (see conversion table below).

20.3.48.2 Extended settings

Smallest Index
Via the
the outputs should start with 0 or with 1.
Number of inputs
Via the
available.
Only send with change
Via the
value shall only be sent if the result of the calculation is different to the previ-
ously calculated result.
20.3.48.3 Conversion table
Number
(converted)
true
Boolean
false
Number ---
Milliseconds
DPTTime
since 1.1.1970
DPTDate Number
237/240
parameter, you can specify whether the numbering of
parameter, you can specify how many inputs shall be
parameter, you can specify whether an output
1
0

Advertisement

Table of Contents
loading