Service call

Error code
Classification
C010
Drive system
related service call
C040
Paper feeding sys-
tem related ser-
vice call
C130
C140
C150
C160
C180
C1A0
C1B0
C260
Scanning system
related service call
C270
C280
C410
Fuser unit related
service call
C430
C440
C450
C550
Optional communi-
(C780)
cation related ser-
vice call
C570
C580
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Contents
Main motor abnormality: The main motor is not rotating
normally.
PFP motor abnormality: The PFP motor is not rotating
normally.
Upper drawer tray abnormality: The upper drawer tray
motor is not rotating or the upper drawer tray is not mov-
ing normally.
Lower drawer tray abnormality: The lower drawer tray
motor is not rotating or the lower drawer tray is not mov-
ing normally.
PFP upper drawer tray abnormality: The PFP upper
drawer tray motor is not rotating or the PFP upper drawer
tray is not moving normally.
PFP lower drawer tray abnormality: The PFP lower
drawer tray motor is not rotating or the PFP lower drawer
tray is not moving normally.
LCF tray-up motor abnormality: The LCF tray-up motor is
not rotating or the LCF tray is not moving normally.
LCF end fence motor abnormality: The LCF end fence
motor is not rotating or the LCF end fence is not moving
normally.
LCF transport motor abnormality: The LCF transport
motor is not rotating normally.
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when power is turned
ON.
Carriage home position sensor not turning OFF within a
specified period of time: The carriage does not shift from
its home position in a specified period of time.
Carriage home position sensor not turning ON within a
specified period of time: The carriage does not reach to
its home position in a specified period of time.
Thermistor or heater abnormality at power-ON: Abnor-
mality of service call the thermistor is detected when
power is turned ON or the temperature of the fuser roller
does not rise in a specified period of time after power is
turned ON.
Thermistor abnormality after abnormality judgment:
Abnormality of the thermistor is detected after a specified
period of time has passed from power-ON (including
ready state).
Heater abnormality after abnormality judgment: The tem-
perature of the fuser roller has exceeded the range of
control (in this case, the main switch turns OFF automati-
cally) or does not even reach the range.
Thermistor abnormality during printing: Abnormality of the
thermistor is detected during printing.
RADF I/F error: Communication error has occurred
between the RADF and the scanner.
Communication error between Engine-CPU and IPC
board
Communication error between IPC board and finisher
2 - 7
07/04
Troubleshooting
P. 5-47
P. 5-48
P. 5-49
P. 5-49
P. 5-50
P. 5-50
P. 5-51
P. 5-52
P. 5-53
P. 5-54
P. 5-55
P. 5-55
P. 5-56
P. 5-57
P. 5-57
P. 5-57
P. 5-58
P. 5-58
P. 5-58
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents