[C150]
PFP upper drawer tray is abnormal
[C160]
PFP lower drawer tray is abnormal
Does the tray go up? (Perform the output check in the test mode: 03-278/280)
l
NO
l
l
l
l
l
l
l
l
l
YES
Is the tray-up sensor working?
(Perform the input check in the test mode: 03-[FAX]OFF/[2]/[H], /[4]/[H])
l
NO
l
l
l
l
l
l
l
l
l
l
l
YES
1) Check if the conductor pattern on the LGC board is short circuited or open circuited.
2) Replace the LGC board.
e-STUDIO200L/202L/203L/230/232/233/280/282/283
TROUBLESHOOTING
1) Check if the connector of the tray-up motor is disconnected.
2) Check if any of the connectors CN241, CN242 and CN244 on the
PFP board is disconnected.
3) Check if the connector CN310 on the LGC board is disconnected.
4) Check if the connector pins are disconnected and the harnesses are
open circuited.
5) Check if the conductor patterns on the PFP board and LGC board
are short circuited or open circuited.
6) Replace the PFP board.
7) Replace the LGC board.
1) Check if the connector of the sensor is disconnected.
2) Check if any of the connectors CN241, CN247 and CN248 on the
PFP board is disconnected.
3) Check if the connector CN310 on the LGC board is disconnected.
4) Check if the slit reaches the sensor.
5) Check if the connector pins are disconnected and the harnesses are
open circuited.
6) Check if the conductor patterns on the PFP board and LGC board
are short circuited or open circuited.
7) Replace the PFP board.
8) Replace the LGC board.