Toshiba e-STUDIO230L Service Handbook page 84

Hide thumbs Also See for e-STUDIO230L:
Table of Contents

Advertisement

Classi-
Code
fication
306
Scanner Image location adjustment
of primary scanning direc-
tion
(scanner section)
308
Scanner Distortion mode
340
Scanner Reproduction ratio adjust-
ment of secondary scan-
ning direction
(scanner section)
354
RADF
Adjustment of
RADF paper
alignment
355
356
RADF
Automatic adjustment of
RADF sensor and
EEPROM initialization
357
RADF
Fine adjustment of RADF
transport speed
358
RADF
RADF sideways deviation
adjustment
359
Scanner Carriage position adjust-
ment during scanning from
RADF
365
RADF
RADF lead-
ing edge posi-
tion
adjustment
366
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Adjustment mode (05) <e-STUDIO200L/230/280>
Func-
Items
tion
ALL
ALL
ALL
for single -
ALL
sided orig-
inal
for double
ALL
sided orig-
inal
ALL
ALL
ALL
ALL
for single -
ALL
sided orig-
inal
for double
ALL
sided orig-
inal
2 - 48
Default
<Accept-
RAM
able
value>
156
SYS
When the value
<0-255>
increases by "1", the
image shifts by approx.
0.0846 mm toward the
front side of the paper.
-
-
Moves carriages to the
adjusting position.
(Chap. 3.2.4)
129
SYS
When the value
<0-255>
increases by "1", the
reproduction ratio in the
secondary scanning
direction (vertical to
paper feeding direction)
increases by approx.
0.223%.
10
SYS
When the value
<0-20>
increases by "1", the
aligning amount
increases by approx.
10
SYS
0.5 mm.
<0-20>
-
SYS
Performs the adjustment
and initialization when
the RADF board or
RADF sensor is
replaced.
50
SYS
When the value
<0-100>
increases by "1", the
reproduction ratio of the
secondary scanning
direction when using the
RADF increases by
approx. 0.1%.
128
SYS
When the value
<0-255>
increases by "1", the
image of original fed
from the RADF shifts
toward the rear side of
paper by approx.
0.0846 mm.
128
SYS
When the value
<0-255>
increases by "1", the car-
riage position when
using the RADF shifts by
approx. 0.1 mm toward
the original feeding side.
50
SYS
When the value
<0-100>
increases by "1", the
copied image of original
fed from the RADF shifts
50
SYS
toward the trailing edge
<0-100>
of paper by approx.
0.1 mm.
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved