Automatic Adjustment Of Sensors And Initialization Of Eeprom - Toshiba e-STUDIO230L Service Handbook

Hide thumbs Also See for e-STUDIO230L:
Table of Contents

Advertisement

3.10.4

Automatic adjustment of sensors and initialization of EEPROM

When any of the PC board, original length sensor, read sensor, reverse sensor is replaced with a new
one, make sure to perform the initialization of EEPROM and adjustment of sensors in the Adjustment
Mode (05).
Perform them after removing all originals on the sensor and closing the RADF.
Also, make sure to adjust the tray volume when the initialization of EEPROM and automatic sensor
adjustment have been performed.
Refer to
P.2-44 "2.2.5 Adjustment mode (05) (e-STUDIO200L/230/280)" for the details.
Errors such as paper jamming may occur if the EEPROM is not initialized and the sensors are not
adjusted after the above mentioned parts were replaced.