Toshiba e-STUDIO230L Service Handbook page 104

Hide thumbs Also See for e-STUDIO230L:
Table of Contents

Advertisement

Adjustment mode (05) <e-STUDIO202L/203L/232/233/282/283>
Classi-
Code
fication
306
Scanner Image location adjustment
of primary scanning direc-
tion
(scanner section)
308
Scanner Distortion mode
340
Scanner Reproduction ratio adjust-
ment of secondary scan-
ning direction
(scanner section)
350
Scanner Shading posi-
tion adjust-
ment
351
354
RADF
Adjustment of
RADF paper
alignment
355
357
RADF
Fine adjustment of RADF
transport speed
358
RADF
RADF sideways deviation
adjustment
359
Scanner Carriage position adjust-
ment during scanning from
RADF
365
RADF
RADF lead-
ing edge posi-
tion
adjustment
366
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Func-
Items
tion
ALL
ALL
ALL
Original
ALL
glass
RADF
ALL
for single -
ALL
sided orig-
inal
for double
ALL
sided orig-
inal
ALL
ALL
ALL
for single -
ALL
sided orig-
inal
for double
ALL
sided orig-
inal
2 - 68
07/11
Default
<Accept-
RAM
able
value>
156
SYS
When the value
<0-255>
increases by "1", the
image shifts by approx.
0.0846 mm toward the
front side of the paper.
-
-
Moves carriages to the
adjusting position.
(Chap. 3.2.4)
129
SYS
When the value
<0-255>
increases by "1", the
reproduction ratio in the
secondary scanning
direction (vertical to
paper feeding direction)
increases by approx.
0.223%.
128
SYS
0.1369 mm/step
<118-
138>
128
SYS
<118-
138>
10
SYS
When the value
<0-20>
increases by "1", the
aligning amount
increases by approx.
10
SYS
0.5 mm.
<0-20>
50
SYS
When the value
<0-100>
increases by "1", the
reproduction ratio of the
secondary scanning
direction when using the
RADF increases by
approx. 0.1%.
128
SYS
When the value
<0-255>
increases by "1", the
image of original fed
from the RADF shifts
toward the rear side of
paper by approx.
0.0846 mm.
128
SYS
When the value
<0-255>
increases by "1", the car-
riage position when
using the RADF shifts by
approx. 0.1 mm toward
the original feeding side.
50
SYS
When the value
<0-100>
increases by "1", the
copied image of original
fed from the RADF shifts
50
SYS
toward the trailing edge
<0-100>
of paper by approx.
0.1 mm.
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Proce-
Contents
dure
1
6
1
1
1
1
1
1
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents