Toshiba e-STUDIO230L Service Handbook page 320

Hide thumbs Also See for e-STUDIO230L:
Table of Contents

Advertisement

(4)
After about two minutes, the value B automatically starts changing.
(5)
After a short time, the value B becomes stable and the display changes as follows.
(6)
Check if the value B is within the range of 235 to 245 (the output voltage range of the auto-toner
sensor is 2.35 V to 2.45 V).
(7)
If the value B is not within the range of 235 to 245, press the Up or Down button to adjust the
value manually.
Note:
Note:
The relation between the button and the values A and B is as follows.
Button to be pressed
Up
Down
(8)
Press the [ENTER] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
(9)
Turn the power OFF.
(10) Install the toner cartridge.
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ADJUSTMENT
230%
TEST MODE
128
B
240%
ADJUSTMENT MODE
128
Value A
Increased
Decreased
100%
[ENTER]
or
TEST MODE
[INTERRUPT]
A3
200
WAIT
128
Fig. 3-3
A3
200
150
A
Fig. 3-4
Value B
Increased
Decreased
A
Fig. 3-5
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved