Classifi-
Code
cation
393
Counter
Number of errors in HDD
(Printer)
398
Laser
Number of polygonal motor
rotational speed switching
399
Laser
Accumulated time of polyg-
onal motor at normal rota-
tion
400
Fuser
Fuser unit error status
counter
404-0
Fuser
Temperature
drop setting in
ready status
404-1
(Center ther-
mistor)
404-2
404-3
405-0
Fuser
Temperature
drop setting in
ready status
405-1
(Side ther-
mistor)
405-2
405-3
407
Fuser
Fuser roller temperature in
ready status
(Side thermistor)
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08) <e-STUDIO200L/230/280>
Default
Func-
<Accept-
Items
tion
value>
PRT
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<0-19>
The first
ALL
drop
<0-10>
The sec-
ALL
ond drop
<0-10>
The third
ALL
drop
<0-10>
The fourth
ALL
drop
<0-10>
The first
ALL
drop
<0-10>
The sec-
ALL
ond drop
<0-10>
The third
ALL
drop
<0-10>
The fourth
ALL
drop
<0-10>
ALL
<0-12>
2 - 103
07/04
RAM
Contents
able
0
SYS
The number of error is
reset at HDD format-
ting.
0
M
Counts the number of
time the polygonal
motor has switched its
rotational speed
between normal rota-
tion and standby rota-
tion.
0
M
Accumulates the time
the polygonal motor has
rotated at normal rota-
tion.
0
M
0: No error
1: C410 (Once)
2: C410 (consecutively
occurred)
3: -
4: C430
5: C440 6: C450
7: C440 8: C450
9: C440 10: C470
11: C470 12: C480
13: C490 14: C470
15: C480 16: C490
17: C470 18: C480
19: C490
1
M
This code is valid only
when "20" is set to 08-
886.
1
M
Setting value x -5°C:
from 0°C to -50°C
1
M
1
M
4
M
4
M
4
M
4
M
8
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Proce-
dure
2
2
2
2
1
4
4
4
4
4
4
4
4
1