[E725]
Stop jam at the read sensor
Is the read roller stained?
YES
NO
Is the read sensor working? (Perform the input check: 03-[FAX]ON/[7]/[G])
l
NO
l
l
l
l
l
l
l
YES
Replace the RADF board.
[E726] Transport/exit signal reception jam
(1)
If the original remains in the RADF, remove it.
(2)
If any paper remains in the equipment, remove it.
(3)
Turn the power OFF and then back ON. If the jam still occurs, lead the following procedure.
(4)
Check the connection between the RADF board and SLG board, and the connection between
the RADF board and switching power supply.
Are the connection of the connectors and joint connectors normal?
Are the connector pins disconnected or are the harnesses open circuited?
(5)
Check if the 24V and 5V outputs of the switching power supply are normal.
(6)
Check if the conductor pattern on the RADF board is short circuited or open circuited.
(7)
Replace the RADF board.
(8)
Check if the conductor pattern on the SLG board is short circuited or open circuited.
(9)
Replace the SLG board.
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Clean the roller.
1) Check if the connector of the read sensor is disconnected.
2) Check if the connector CN6 on the RADF board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are
open circuited.
4) Check if the conductor pattern on the RADF board is short circuited
or open circuited.
5) Replace the read sensor.
6) Replace the RADF board.
5 - 31
05/05
e-STUDIO200L/202L/203L/230/232/233/280/282/283
TROUBLESHOOTING