Change the setting of he DIP switch on the finisher control PC board.
Change all the setting of the DIP switch (1-8) to OFF.
Note:
Note:
Record the current settings of the DIP switch before changing them. After the updating is com-
pleted, return the DIP switch to the status as record.
(6)
Turn ON the power while [0] button and [8] button are pressed simultaneously.
Updating starts automatically and the LED on the download jig lights.
(7)
After the update is completed properly, the LED on the download jig blinks slowly. The LED starts
blinking in approx. 20 sec. since the update starts. It is assumed that the update is failed if it does
not start blinking even though 1 min. has passed, or LED flashes fast. In this case, turn OFF the
power and check the following items. Then, clear the problem and restart updating from the
beginning.
Is the download jig connected properly?
Is the ROM installed to the download jig properly?
Is the updating data written on the ROM of the download jig properly?
Do the download jig and the equipment operate properly?
Is the DIP switch on the finisher control PC board set properly?
(8)
Turn OFF the power, remove the download jig and return the DIP switch to the status before
updating.
(9)
Install the finisher rear cover.