Toshiba e-STUDIO230L Service Handbook page 333

Hide thumbs Also See for e-STUDIO230L:
Table of Contents

Advertisement

[C] Image position adjustment of the primary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3)
Press [FAX] to make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment
(Refer to *).
* Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4)
Measure the distance B from the left edge of the paper to 10 mm of the copied image of the ruler.
(5)
Check if the distance B is within the range of 10±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
(Key in a value (acceptable values: 0 to 255))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
("100% A" is displayed.)
* The smaller the adjustment value is, the more the image is shifted to the left and the distance
B becomes narrower (0.085 mm/step).
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
(Key in the code [306])
Copied image of the ruler
Feeding direction
Fig. 3-13
3 - 15