Service Call - Toshiba e-STUDIO520 Service Handbook

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

2.1.2

Service call

Error code
Classification
C130
Paper feeding sys-
tem related ser-
vice call
C140
C150
C160
C180
C1A0
C1C0
C260
Scanning system
related service call
C270
C280
C360
Process related
service call
C370
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Contents
1st drawer tray abnormality: The tray-up motor-1 does
not run normally or the 1st drawer tray does not move
normally.
(Feeding of any other drawer than the 1st drawer is pos-
sible.)
2nd drawer tray abnormality: The tray-up motor-1 does
not run normally or the 2nd drawer tray does not move
normally.
(Feeding of any other drawer than the 2nd drawer is pos-
sible.)
3rd drawer tray abnormality: The tray-up motor-2 does
not run normally or the 3rd drawer tray does not move
normally.
(Feeding of any other drawer than the 3rd drawer is pos-
sible.)
4th drawer tray abnormality: The tray-up motor-2 does
not run normally or the 4th drawer tray does not move
normally.
(Feeding of any other drawer than the 4th drawer is pos-
sible.)
Tandem LCF tray-up motor abnormality: The Tandem
LCF tray-up motor does not run normally or the Tandem
LCF tray does not move normally.
(Feeding of any other drawer than the Tandem LCF is
possible.)
Tandem LCF end fence motor abnormality: The Tandem
LCF end fence motor does not run normally or the Tan-
dem LCF end fence does not move normally.
(Feeding of any other drawer than the Tandem LCF is
possible.)
Option LCF tray-up motor abnormality: The Option LCF
tray-up motor does not run normally or the Option LCF
tray does not move normally.
(Feeding of any other drawer than the Option LCF is pos-
sible.)
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when the power is
turned ON.
Carriage home position sensor not turning OFF within a
specified period of time: The carriages do not shift from
their home position within a specified period of time.
Carriage home position sensor not turning ON within a
specified period of time: The carriages do not reach their
home position within a specified period of time.
Wire cleaner drive motor abnormality: The wire cleaner
drive motor does not run normally or the charger wire
cleaner does not move normally.
Transfer belt cam motor abnormality: The transfer belt
cam motor does not run normally when the power is
turned ON or the copying is started.
2 - 9
Troubleshooting
Ch.5.1.6
Ch.5.1.6
Ch.5.1.6
Ch.5.1.6
Ch.5.1.6
Ch.5.1.6
Ch.5.1.6
Ch.5.1.7
Ch.5.1.7
Ch.5.1.7
Ch.5.1.13
Ch.5.1.13
e-STUDIO520/523/600/603/720/723/850/853
ERROR CODE AND SELF-DIAGNOSTIC MODE
2