Toshiba e-STUDIO230L Service Handbook page 503

Hide thumbs Also See for e-STUDIO230L:
Table of Contents

Advertisement

[C180]
LCF tray-up motor is abnormal
Does the tray move? (Perform the output check in the test mode: 03-271)
l
NO
l
l
l
l
l
l
l
l
l
YES
Are the LCF tray bottom sensor and LCF tray-up sensor working?
(Perform the input check in the test mode: 03-[FAX]OFF/[5]/[F], /[3]/[A])
NO
l
l
l
l
l
l
l
l
l
l
l
l
YES
1) Check if the conductor pattern on the LGC board is short circuited or open circuited.
2) Replace the LGC board.
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
1) Check if the connector of the LCF tray-up motor is disconnected.
2) Check if any of the connectors CN100, CN101 and CN103 on the
LCF board is disconnected.
3) Check if the connector CN310 on the LGC board is disconnected.
4) Check if the connector pins are disconnected and the harnesses are
open circuited.
5) Check if the conductor patterns on the LCF board and LGC board are
short circuited or open circuited.
6) Replace the LCF board.
7) Replace the LGC board.
1) Check if the connectors of the sensors are disconnected.
2) Check if any of the connectors CN100, CN104 and CN105 on the
LCF board is disconnected.
3) Check if the connector CN310 on the LGC board is disconnected.
4) Check if the slit reaches the sensors.
5) Check if the connector pins are disconnected and the harnesses are
open circuited.
6) Check if the conductor patterns on the LCF board and LGC board are
short circuited or open circuited.
7) Replace the LCF board.
8) Replace the LGC board.
5 - 51
e-STUDIO200L/202L/203L/230/232/233/280/282/283
TROUBLESHOOTING
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents