[ 3 ] Paper jam in finisher section
[EA10]
Paper transport delay jam
MJ-1022
Is there any paper remaining on the transport path in the finisher or equipment?
YES
NO
Is the connector J10 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and inlet sensor (S2) open cir-
cuited?
YES
NO
Is the inlet sensor working normally? (Check the movement of the actuator.)
l
NO
l
YES
Replace the finisher controller PC board.
MJ-1025
Is there any paper remaining on the transport path in the finisher or equipment?
YES
NO
Is the connector CN16 (inlet sensor) on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and inlet sensor open-circuited?
YES
NO
Is the inlet sensor working normally? (Check the movement of the actuator.)
l
NO
YES
Replace the finisher controller PC board.
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Remove the paper.
Connect the connector securely. Replace the harness.
1) Connect the connector of the inlet sensor securely.
2) Attach the actuator securely if its shaft is out of place.
3) Replace the inlet sensor.
Remove the paper.
Connect the connector securely. Replace the harness.
1) Attach the actuator securely if its shaft is out of place.
2) Replace the sensor.