4.7.7.a. Loop History Information
On the Loop Detection Configuration Menu, pressing "I" opens the Loop History Information
screen, as shown in Fig. 4-7-26. On this screen, the date and time of detecting loop and
the event information are listed.
PN28160/PN28160A Local Management System
Loop Detection Configuration Menu -> Loop History Information
Entry Time(YYYY/MM/DD HH:MM:SS)
----- -------------------------
-------------------------------- <COMMAND> -----------------------------------
[N]ext Page
[P]revious Page
[C]lear Loop Detection history
[Q]uit to previous menu
Command>
Enter the character in square brackets to select option
Screen Description
Entry
Shows the event number.
Time
Shows the time when the event occurred. If the time is not set, the accumulated running time
since boot is shown.
Event
Shows the description of the event occurred to the Switching Hub.
The loop detected on portX.
The loop detected between portX
and portY.
PortX auto recovery.
Available commands are listed below.
N
Show the next page.
Press "N." The screen shows the next page.
P
Show the previous page.
Press "P." The screen shows the previous page.
C
Delete the history information in the loop history function.
Q
Return to the previous menu.
-------------------------------------------
Fig. 4-7-26 Loop History Information
Indicates that a loop was detected in a Switching Hub under
port X, and the connection has been shut down.
Indicates that a loop was detected between port X and port
Y, and the connection has been shut down.
Indicates that the port X is automatically recovered from being
shut down.