Sensor (Bridge Media Exit) Late Jam - Lexmark X95x series Service Manual

Hide thumbs Also See for X95x series:
Table of Contents

Advertisement

7558-xxx
Step
Action and questions
Perform a print test.
6
Does the error remain?

402.03 Sensor (bridge media exit) late jam

Step
Action and questions
Check the media path.
1
Is the media path free of any
media fragments?
Check the sensor (bridge media
2
exit) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (bridge media
entrance).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Check the sensor (bridge media
3
exit) for proper connection.
Is the above component
properly connected?
Check the bridge drive motor for
4
proper operation.
Caution: When
performing motor
tests, ensure that all
cover and door
interlock switches
are overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Finisher Motor Tests.
4. Touch Bridge unit motor.
Does the above component
operate properly?
Check the bridge drive motor for
5
proper connection.
Is the above component
properly connected?
Service Manual
2-212
Yes
Replace the finisher controller
card assembly.
Go to
"Finisher PCBA removal"
on page
4-350.
Yes
Go to step 2.
Go to step 4.
Replace the sensor(bridge media
exit).
Go to
"Sensor (bridge media
exit) removal" on page
4-311.
Go to step 6.
Replace the bridge drive motor.
Go to
"Bridge drive motor
removal" on page
4-300.
Go to step 6.
No
Problem resolved
No
Remove any media or media
fragments.
Go to step 3.
Replace the connection.
Go to step 5.
Replace the connections.
Previous
Next
Go Back

Advertisement

Table of Contents
loading

Table of Contents