7558-xxx
Step
Action and questions
Check the document tray media
2
guide position.
Are the document tray media
guides set correctly?
Check the sensor (ADF
3
document tray width 1) for proper
operation.
th 3) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
document tray width 1).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Check the sensor (ADF
4
document tray width 2) for proper
operation.
th 3) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
document tray width 2).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Check the sensor (ADF
5
document tray width 3) for proper
operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch ADF/SCANNER
SENSOR TESTS.
4. Touch Sensor (ADF
document tray width 3).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Service Manual
2-162
Yes
Go to step 3.
Go to step 4.
Go to step 5.
Go to step 6.
No
Adjust the document tray media
guides to the proper position.
Replace the ADF document tray.
Go to
"ADF document tray
removal" on page
4-202.
Replace the ADF document tray.
Go to
"ADF document tray
removal" on page
4-202.
Replace the ADF document tray.
Go to
"ADF document tray
removal" on page
4-202.
Previous
Next
Go Back