381.26 Sensor (decurler cam HP) late jam

Step
Action and questions
Check the sensor (decurler cam
1
HP) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (decurler cam
HP).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
2
Is the sensor (decurler cam HP)
properly connected?
Check the bridge decurler cam
3
clutch for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Decurler cam clutch.
Does the above component
make an audible clicking
sound?
4
Is the bridge decurler cam
clutch properly connected?
Check the bridge unit drive motor
5
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Bridge unit motor.
Does the above component
operate properly?
Service Manual
2-190
Yes
Go to step 3.
Replace the sensor (decurler
cam HP). Go to
"Sensor
(decurler cam HP) removal" on
page
4-315.
Go to step 5.
Replace the decurler clutch. Go
to
"Decurler clutch removal"
on page
4-307.
Go to step 7.
No
Go to step 2.
Replace the connection.
Go to step 4.
Replace the connection.
Go to step 6.